Home > Product > Accura3500S
|
|
| |
|
| |
|
 |
Voltage, current, power, energy, PF, Hz
|
 |
Basic module:
DIO module[digital input/output, 8/2channels |
 |
Extension module[option]:
DI/DO/AI/AO module |
 |
RS485, Modbus RTU
protocol
|
| |
|
|
|
|
 |
|
Power Measurements, Digital/Analog Input and Output Integration
|
|
Accura 3500S is a high accuracy digital
power meter, suited to power measurements and digital/analog input and output. This
enables customers to easily meet a variety of digital/analog requirements in
the field, remarkably cutting down expenses of customers to additionally
purchase separate RTU products in existing management system. The device is
applied to applications, such as electrical facilities, intelligent building
system, factory and etc.
|
| |
| Accuracy, Power Quality
|
|
The measuring accuracy is the most
important criterion to evaluate the reliability of energy management system. Actually
low accuracy makes it hard for customers to precisely manage energy, causing
inequality of energy between incoming feeder and sum of load sides. Accura 3500S
makes ±0.2% high accuracy measurements for
voltage and current, and conforms to IEC62053-22 class 0.5S for power and
energy. This makes it possible to solve the problem with energy inequality. Furthermore
the device provides the information of power qualities, such as voltage/current
THD, harmonic analysis, and k factor.
|
| |
| CE/UL Safety and Reliability
|
|
The structure-
framework, circuit, fire - of Accura 3500S conforms to safety standard,
CE[IEC61010], UL[UL61010-2, 2nd edition]. Particularly the device
provides pass-through busbar, allowing CT leads to be terminated on the device.
This eliminates any possible point of failure at the device. And optic
interface between meter and module essentially disturbs danger of the existing electrical
contacts.
|
| |
| Easy Adding of Modules
|
|
Easy
adding of modules to rear side of meter provides customized extension of
function to flexibly meet a variety of
applications. Accura 3500S has a basic module, called DIO module, and an
extension module, one of digital input, digital output, analog input, and
analog output modules. the extension module is selected as an option when
ordering.
|
| |
| Communication[IrDA and RS485]
|
|
Accura
3500S provides two independent communication ports. One port provides RS485
communication which supports a variety of applications, such as energy management,
IBS, and SCADA. The Accura also has an optical IrDA port, allowing the device
to be set up and programmed using a UMPC. Just point at the meter with
IrDA-equipped UMPC, so customers can monitor measurements, harmonic graph,
vector diagram, demand trend, and oscilloscope.
|
|
|
|

|
|
|
Measurement
|
|
|

|
64 Sampling/Cycle True RMS
|
|
|

|
IEC 62053-22 Class 0.5S
|
| |

|
50, 60Hz
|
| |

|
4 Quadrant Energy |
| |
|
- kWh/kVARh received, delivered
|
| |
|
- kWh/kVARh net
|
| |
|
- kWh/kVARh total
|
|
|

|
Phase voltage, line to line voltage, current |
|
|

|
Active power, reactive power, active energy, reactive energy¢Ó, PF, Hz
|
|
|

|
Fundamental component¢Ó, True RMS of current
|
|
|

|
4 Quadrant Power
|
|
|

|
Demand, peak demand |
| |

|
Maximum, minimum¢Ó
|
|
|
Power Quality
|
|
|

|
Voltage/current THD
|
|
|

|
Harmonic Analysis¢Ó
|
|
|

|
k factor¢Ó
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IrDA Communication
|
|
|

|
Harmonic graph
|
| |

|
Vector diagram
|
|
|

|
Demand trend
|
|
|

|
Oscilloscope
|
|
|

|
Module status/operation |
|
|
Communications
|
|
|

|
RS485 port[rear]
|
|
|
|
- Modbus RTU protocol
|
|
|
|
- Baudrate: 1,200 ~ 57,600bps
|
|
|

|
IrDA port[front]
|
|
|
|
|
|
|
|
|
|
Basic Module
|
|
|

|
DIO module: digital input/output 8/2 channels |
|
|
|
|
|
Extension Module[option]
|
| |

|
DI module: digital input 12 channels |
| |

|
DO module: digital output 4 channels |
| |

|
AI module: analog input 6 channels |
| |

|
AO module: analog output 6 channels |
|
|
Power Supply
|
|
|

|
DC 100 ~ 300V
|
|
|

|
AC 85 ~ 265V, 50/60Hz
|
| |

|
Burden 10VA |
|
|
|
¢Ó RS485
Åë½Å¿¡¼ µ¥ÀÌÅÍÃëµæ °¡´É
|
|

|
|
|
True RMS Measurement robust to harmonics
|
|
Most
of energy environments consist of nonlinear loads, such as industrial load,
rectifier, power electronic device, electric furnace and etc. this causes fatal
distortion of voltage and current waveforms. Accura 3500S makes high accuracy
True RMS measurements for voltage and current distorted with harmonics.
|
|
|
| Power Quality Analysis
|
|
Accura
3500S provides k factor, analysis of voltage and current up to 31st
harmonic, and realtime waveform of voltage and current.
|
|
|
|
Module structure to adapt to requirements in the field
|
|
Easy
adding of modules to rear side of meter provides customized extension
capability to flexibly meet a variety of
applications. In the case of the existing IBS, DDC panel concentrates all of
input/output wiring, decreasing economical efficiency and reliability of the
overall system. Accura 3500 easily replaces the existing DDC panel, building
the optimal IBS system.
|
|
|
|
Compatibility with Analog meters
|
|
Accura
3500S mounts directly in ANSI C39.1[4¡± Round] or DIN 96. this is perfect for new
installations and for existing panels. In new installations, simply use
existing DIN or ANSI punches. For existing panels, pull out old analog meters
and fit the device in its cutout.
|
|
|
|
High Reliability Energy Management
|
|
The
most important point to evaluate the overall data reliability of energy
management is the accuracy of meters. Accura 3500S makes ±0.2% high accuracy measurements for voltage and current, and conforms to IEC62053-22 class
0.5S for power and energy. Energy management gives customers various services,
monitoring, cost curtailment, demand, energy planning, and etc.
|
|
|
|
|